Light Speed 2 in 1 Laser Hair and Tattoo Removal Machine – 7 Upgradeable Configurations with TEC Cooling | ZENI

$1,479.00

🚢
Free Shipping
3-5 days · Tracking

🛡️
After-Sales Support
2-year service · Tech support

✅
CE Certified
Professional grade

Get instant quote & assistance

100 in stock

Description

ZENI · LIGHT SPEED 2-IN-1 · 7 CONFIGURATIONS · TEC COOLING OPTION

Seven Configuration Paths. One Platform That Adapts to Your Clinic.

The Light Speed 2 in 1 laser hair and tattoo removal machine offers the most extensive configuration matrix in the ZENI 5000W series — seven distinct upgrade paths including 6Bar+FAC, 10Bar, 10Bar+FAC, 10Bar+磁吸手柄, 12Bar+TEC冷却, 16Bar+磁吸手柄 and 16Bar+FAC, with 4 to 6 wavelengths. This breadth means a clinic can select the exact combination of power, beam quality, cooling performance and handle convenience that matches its treatment volume and patient comfort requirements. Clinical data supports both modalities: 808nm diode laser achieves 57.9% mean hair reduction after three sessions in Fitzpatrick IV–VI skin, and 1064nm picosecond laser delivers 78.1% excellent tattoo clearance versus 54.4% for nanosecond systems, with fewer treatment sessions (3 vs. 4, p=0.020).

7 CONFIGURATIONS

6Bar+FAC → 16Bar+FAC

The most extensive upgrade matrix in the ZENI 5000W line, including TEC cooling and magnetic handle options.

12BAR+TEC COOLING

Comfort at Higher Power

TEC cooling maintains a comfortable contact temperature (~4°C) even as the Bar count increases.

MAGNETIC HANDLE OPTIONS

10Bar / 16Bar Magnetic

Magnetic handle connection simplifies handpiece attachment and switching during treatment.

CLINICAL REFERENCE

57.9% / 78.1%

57.9% hair reduction after 3 sessions (Fitzpatrick IV–VI); 78.1% excellent tattoo clearance with picosecond 1064nm.

Why Seven Configuration Options Change the Purchasing Equation

Most laser platforms offer two or three upgrade paths. The Light Speed 2 in 1 goes further with seven — each addressing a different clinical or operational priority. A clinic focused on cost efficiency can select 6Bar+FAC as an entry point. A clinic prioritising raw power without FAC can choose 10Bar. One seeking a balance of power and beam quality can choose 10Bar+FAC. A clinic that values handle convenience can opt for the 10Bar or 16Bar magnetic handle configurations. And a clinic that places patient comfort at the top of its priority list can select the 12Bar+TEC cooling configuration, where thermoelectric cooling maintains a low contact temperature even at higher power levels. The 16Bar+FAC configuration remains the flagship for maximum throughput and beam quality. The clinical foundation of both modalities is well documented. 808nm diode laser achieves 57.9% mean hair reduction after three sessions in Fitzpatrick IV–VI skin, with 100% patient satisfaction and no cases of keloid formation, scarring, infection or pigmentary changes.[reference:6] FAC (Fast Axis Collimation) lenses collimate the fast axis of each laser bar; experimental data shows fiber coupling efficiency can reach 89% with properly aligned FAC optics, and a 4μm displacement error can reduce efficiency by 78.5%.[reference:7][reference:8] TEC cooling can bring the sapphire contact surface to approximately 4°C, improving comfort during treatment.[reference:9] On the picosecond side, 1064nm picosecond laser achieves 78.1% excellent tattoo clearance versus 54.4% for Q-switched nanosecond, with a median of 3 sessions versus 4 (p=0.020).[reference:10] A 755nm picosecond randomized split-tattoo trial reported satisfactory clearance in 73.3% of cases versus 23.3% for nanosecond lasers (p=0.0003).[reference:11] With seven configuration paths — from 6Bar+FAC to 16Bar+FAC, including TEC cooling and magnetic handle options — the Light Speed 2 in 1 allows a clinic to match the platform to its exact clinical and operational priorities, rather than compromising on a one-size-fits-all configuration. Explore our professional diode laser hair removal equipment for related service planning.

01 / Treatment Applications

Diode Laser Hair Removal

The 808nm diode handpiece targets melanin in the hair follicle. Clinical data in Fitzpatrick IV–VI skin shows 57.9% mean hair reduction in the underarm and 56.7% in the chin after three sessions, with 100% patient satisfaction and no cases of keloid formation, scarring, infection or pigmentary changes.[reference:12] The 4–6 wavelength configuration allows operators to tailor treatment across different skin types and hair colors. Common treatment areas include underarms, bikini line, legs, arms, back, chest and face. Multiple sessions are typically required because hair grows in cycles.

Picosecond Tattoo Removal

The dedicated picosecond handpiece delivers ultra-short pulses that shatter tattoo ink through a photoacoustic effect. Clinical comparisons demonstrate superior clearance versus nanosecond systems: 1064nm picosecond laser achieves 78.1% excellent clearance versus 54.4% for Q-switched nanosecond (p=0.029), with a median of 3 sessions versus 4 (p=0.020).[reference:13] A 755nm randomized split-tattoo trial reported satisfactory clearance in 73.3% of picosecond cases versus 23.3% for nanosecond (p=0.0003).[reference:14] Ink colour, depth and tattoo history affect treatment planning and the number of sessions required.

Pigment Removal & Skin Rejuvenation

The picosecond handpiece also addresses benign pigmented lesions, freckles, sun spots and uneven skin tone. The photoacoustic mechanism breaks pigment particles into smaller fragments for immune clearance. Depending on the wavelength configuration included with the selected package, the platform can support pigment-focused and skin rejuvenation protocols alongside hair and tattoo removal.

Scalable Treatment Capacity

The seven-configuration matrix means treatment capacity and operational convenience scale independently. A clinic focused on high-volume hair removal can upgrade Bar count for faster coverage. A clinic prioritising patient comfort can select the 12Bar+TEC configuration. A clinic that values workflow efficiency can choose magnetic handle options. The platform adapts to different clinical priorities without requiring a complete system replacement.

02 / How the 7-Configuration Platform Works

The Seven Configuration Paths Explained

6Bar+FAC: entry configuration with FAC collimation for efficient energy delivery. 10Bar: higher total power without FAC lenses. 10Bar+FAC: combines higher Bar count with FAC collimation for a balance of power and beam quality. 10Bar+磁吸手柄: 10Bar power with a magnetic handle connection for simplified handpiece attachment. 12Bar+TEC冷却: higher Bar count with thermoelectric cooling to maintain comfortable contact temperature. 16Bar+磁吸手柄: flagship-level power with magnetic handle convenience. 16Bar+FAC: maximum power with FAC collimation for the highest throughput and beam quality.

FAC Technology and Alignment Precision

FAC (Fast Axis Collimation) lenses collimate the fast axis of each laser bar, focusing the beam for efficient fiber coupling. Experimental data shows coupling efficiency can reach 89% with properly aligned FAC optics, and a 4μm displacement error can reduce efficiency by 78.5%.[reference:15][reference:16] The 6Bar+FAC, 10Bar+FAC and 16Bar+FAC configurations include FAC.

TEC Cooling for Patient Comfort

The 12Bar+TEC冷却 configuration integrates thermoelectric cooling (TEC) into the handpiece. TEC can cool the sapphire contact surface to approximately 4°C, improving comfort during treatment and protecting the epidermis at higher power levels.[reference:17] This is particularly relevant for clinics that treat sensitive areas or patients who prioritise comfort during hair removal sessions.

Picosecond Laser Mechanism

Picosecond lasers deliver pulses in the trillionths of a second, creating a photoacoustic pressure wave that shatters tattoo ink and pigment particles into smaller fragments. This mechanical fragmentation allows the body’s immune system to clear the particles more efficiently than purely photothermal nanosecond systems, which is why clinical comparisons consistently show higher excellent clearance rates and fewer sessions for picosecond lasers. Learn more about laser-based treatment technology for clinical background.

03 / Product Configuration
System Type Light Speed 2-in-1 diode + picosecond laser platform
Configurations 6Bar+FAC / 10Bar / 10Bar+FAC / 10Bar+磁吸手柄 / 12Bar+TEC冷却 / 16Bar+磁吸手柄 / 16Bar+FAC
Wavelengths 4–6 wavelengths (exact combination to be confirmed)
Core Applications Hair removal, tattoo removal, pigment removal, skin rejuvenation
Certification CE certified

Per-handle output power, specific wavelength combinations for the 4- and 6-wavelength configurations, picosecond wavelength options, pulse duration, spot size, screen size, cooling system details (TEC temperature, water/air components), dimensions, weight and voltage should be confirmed in the model-specific specification sheet for the selected configuration.

04 / Buyer Questions

What are the seven configuration options, and which should I choose?

The seven options are 6Bar+FAC, 10Bar, 10Bar+FAC, 10Bar+磁吸手柄, 12Bar+TEC冷却, 16Bar+磁吸手柄 and 16Bar+FAC. Choose based on priority: cost efficiency (6Bar+FAC), raw power (10Bar), power with beam quality (10Bar+FAC), handle convenience (magnetic options), patient comfort at higher power (12Bar+TEC), or maximum throughput (16Bar+FAC).

What makes the 12Bar+TEC cooling configuration different?

The 12Bar+TEC configuration adds thermoelectric cooling to the handpiece. TEC can cool the sapphire contact surface to approximately 4°C, improving comfort and protecting the epidermis at higher power levels.[reference:18] This is the configuration to choose if patient comfort during treatment is a top priority.

What clinical evidence supports the hair removal and tattoo removal applications?

For hair removal: 808nm diode laser achieves 57.9% mean hair reduction after three sessions in Fitzpatrick IV–VI skin, with 100% patient satisfaction and no cases of keloid formation, scarring, infection or pigmentary changes.[reference:19] For tattoo removal: 1064nm picosecond laser achieves 78.1% excellent clearance versus 54.4% for nanosecond systems, with fewer median sessions (3 vs. 4, p=0.020).[reference:20] 755nm picosecond achieved satisfactory clearance in 73.3% of cases versus 23.3% for nanosecond (p=0.0003).[reference:21]

Why does FAC matter, and which configurations include it?

FAC lenses collimate the fast axis of each laser bar, improving fiber coupling efficiency. Experimental data shows coupling efficiency can reach 89% with properly aligned FAC optics, and a 4μm displacement error can reduce efficiency by 78.5%.[reference:22][reference:23] The 6Bar+FAC, 10Bar+FAC and 16Bar+FAC configurations include FAC.

What should I request with the quotation?

Ask for the model-specific specification sheet covering the selected configuration, specific wavelengths in the 4- and 6-wavelength options, picosecond wavelength configuration, per-handle output power, pulse duration, spot size, screen size, cooling system details (TEC temperature, water/air components for the TEC configuration), dimensions, weight and voltage. Confirm the complete accessory list including both handpieces, protective eyewear and power cord. Verify CE or relevant certification documentation for your market.

7 CONFIGURATIONS · TEC COOLING · MAGNETIC HANDLE OPTIONS

Choose the Configuration That Fits Your Clinic

Contact ZENI with your target configuration (including TEC cooling or magnetic handle preferences), wavelength requirements, treatment volume and order quantity. Request a quotation covering the system, selected upgrade path, both handpieces, accessories and support needed for your hair removal and tattoo removal services.

Reviews

There are no reviews yet.

Be the first to review “Light Speed 2 in 1 Laser Hair and Tattoo Removal Machine – 7 Upgradeable Configurations with TEC Cooling | ZENI”

Your email address will not be published. Required fields are marked *